Revision 62edbcc8c6021789df156749d71229308ba4313a authored by Ronald Burkey on 08 August 2021, 00:25:00 UTC, committed by GitHub on 08 August 2021, 00:25:00 UTC
yaAGCb1: Fixed a few errors identified by SELF-CHECK
2 parent s 1bd6f8f + b8b57e2
Raw File
AGC_BLOCK_II_INTERPRETIVE_CODES_ASSEMBLY_RULES_FOR_BLK2.argus
# Copyright:    Public domain.
# Filename:     AGC_BLOCK_II_INTERPRETIVE_CODES_ASSEMBLY_RULES_FOR_BLK2.mitigus
# Purpose:      Part of the source code for YUL (revision 9).
# Assembler:    TBD
# Contact:      Jim Lawton <jim.lawton@gmail.com>
# Website:      https://www.ibiblio.org/apollo/index.html
# Page scans:   https://archive.org/details/yulsystemsourcec00hugh
# Pages:        014-017 (4)
# Mod history:  2016-10-06 JL   Created.
#               2016-10-08 JL   Transcribed.

# Annotations:
#
#   B L A I R - S M I T H
#    Y U L   S Y S T E M
#
#       Listings in
#    MITIGUS  Format
#

# Note: Page numbers are scan page numbers rather than listing.

L      @AGC BLOCK II INTERPRETIVE CODES: ASSEMBLY RULES FOR BLK2

# Page 14
#      @AGC BLOCK II INTERPRETIVE CODES: ASSEMBLY RULES FOR BLK2                 USER'S OWN PAGE NO.   1        PAGE  11

R0001   SUFFIX 01 CODES, INDEXABLE (EXCEPT SETPD) BY ADDING 10 TO SUFFIX.       FOR A KEY TO DATA MODES, SEE PAGE 2.

R0002                   ADDR   PUSH  MODE   OP   MODE  RH  OCT   OCT*  ALTERNATE                ADDRESS CODES
R0003                   TYPE    UP    IN   MODE  OUT   OP  CODE  CODE  SPELLING          (167777 WILL BE LAST ACM ADDR)

 0005   00       VLOAD  A14    YES   -     V      V        001   003               A14   ANY 14-BIT ADDRESS -- 0-52,
 0007   01       TAD    A14    YES   DT    T      -        005   007                     100-3777, IF LOCATION IN BANK
 0009   02       SIGN   E      YES   -     D      -        011   013                     17 OR LESS THEN 20000-47776, IF
 0011   03       VXSC   A14    YES   DT/V  V/D    V        015   017                     LOCATION IN BANK 21 OR MORE
 0013   04       CGOTO  E+F    NO    -     S      U   YES  021   023                     THEN 52000-167777.  STORED IN
 0015   05       TLOAD  A14    YES   -     T      T        025   027                     ARC-CCS FASHION, COMPLEMENTED
 0017   06       DLOAD  A14    YES   -     D      D        031   033                     IF INDEXED BY X2.
 0019   07       V/SC   A14    YES   DT/V  V/D    V        035   037                     *** SEE ALSO E & F BELOW. ***

 0021   10       SLOAD  A14    NO    -     S      D        041   043               E     ERASABLE -- 0-52, 100-3777.
 0023   11       SSP    E+C    NO    -     S      -        045   047                     STORED IN ARC-CCS FASHION,
 0025   12       PDDL   A14    YES   -     D      D        051   053                     COMPLEMENTED IF INDEXED BY X2.
 0027   13       MXV    A14    NO    V     M      -        055   057                     *******************************
 0029   14       PDVL   A14    YES   -     V      V        061   063                     ALL INTERPRETIVE ADDRESSES
 0031   15       CCALL  E+F    NO    -     S      U   YES  065   067                     REFERRING TO ERASABLE ARE PUT
 0033   16       VXM    A14    NO    V     M      -        071   073                     INTO ADRES (10 BIT) FORM AND
 0035   17       NORM   E      NO    DT    S      -        075   077    SLC              ARE CHECKED FOR CORRECT EBANK.

 0036   20       DMPR   A14    YES   DT    D      D        101   103               F     FIXED -- 20000-167777.  STORED
 0038   21       DDV    A14    YES   DT    D      -        105   107                     AS IS.  ***********************
 0040   22       BDDV   A14    YES   DT    D      -        111   113                     ALL INTERPRETIVE ADDRESSES
 0042   23  (GEN SHIFT)                                                                  REFERRING TO FIXED ARE PUT INTO
 0044   24       VAD    A14    YES   V     V      -        121   123                     FCADR FORM BEFORE ALTERATIONS
 0046   25       VSU    A14    YES   V     V      -        125   127                     SUCH AS TRUNCATING TO 14 BITS.
 0048   26       BVSU   A14    YES   V     V      -        131   133
 0049   27       DOT    A14    YES   V     V      D        135   137

 0050   30       VXV    A14    YES   V     V      -        141   143               C     CONSTANT -- ANY TYPE OF SINGLE-
 0052   31       VPROJ  A14    YES   V     V      -        145   147                     PRECISION CONST.  STORED AS IS.
 0054   32       DSU    A14    YES   DT    D      -        151   153
 0055   33       BDSU   A14    YES   DT    D      -        155   157            ----------------------------------------
 0056   34       DAD    A14    YES   DT    D      -        161   163            RH OP: INDICATES THOSE CODES THAT SHOULD
 0057   35                                                                      BE RIGHT-HAND OPERATORS, OR OTHERWISE
 0058   36       DMP    A14    YES   DT    D      -        171   173            SHOULD BE ACCOMPANIED BY A BLANK RIGHT-
 0059   37       SETPD  E      NO    -     S      -        175   ---            HAND OPERATOR.

 0060   40       CCLRB  E+F    NO    -     S      B   YES  065   067


R0061   GENERAL SHIFT CODES, SUFFIX 01 CODE 23.                                 **** DEFINITION: ARC-CCS(X) = X + SGN(X)

R0062                   MODE  UAL  UAU  IAL   IAU   ADAD   OCT   OCT*                           ADDRESS CODES

 0064   0        SL      DT   -51   51  -177  177  00200   115   117            UAL -- UNINDEXED ADDRESS LOWER LIMIT
 0066   1        SR      DT   -51   51  -177  177  00600   115   117            UAU -- UNINDEXED ADDRESS UPPER LIMIT
 0068   2        SLR     D    -34   15  -177  177  01200   115   117            IAL -- INDEXED ADDRESS LOWER LIMIT
 0070   3        SRR     D    -15   34  -177  177  01600   115   117            IAU -- INDEXED ADDRESS UPPER LIMIT
 0072   4        VSL     V    -34   33  -177  177  00200   115   117            ADAD -- ADDITIVE FOR ADDRESS
 0074   5        VSR     V    -33   34  -177  177  00600   115   117            FINISHED ADDRESS STORED LIKE A14 OR E.

# Page 15
#      @AGC BLOCK II INTERPRETIVE CODES: ASSEMBLY RULES FOR BLK2                 USER'S OWN PAGE NO.   2        PAGE  12

P0078   SUFFIX 10 CODES, NOT INDEXABLE.

R0079                   ADDR  MODE  RH  OCT   ALTERNATE
R0080                   TYPE  OUT   OP  CODE  SPELLING                                          ADDRESS CODES

 0082   00       AXT,2   C     -        002                                        A     ANY 15-BIT ADDRESS -- 0-52,
 0084   01       AXT,1   C     -        006                                              100-3777, 20000-167777.  STORED
 0086   02       AXC,2   C     -        012                                              AS IS.
 0088   03       AXC,1   C     -        016
 0090   04       LXA,2   E     -        022
 0091   05       LXA,1   E     -        026                                        E     ERASABLE -- 0-52, 100-3777.
 0093   06       LXC,2   E     -        032                                              STORED AS IS.
 0095   07       LXC,1   E     -        036

 0096   10       SXA,2   E     -        042                                        F     FIXED -- 20000-167777.  STORED
 0098   11       SXA,1   E     -        046                                              AS IS.
 0100   12       XCHX,2  E     -        052
 0101   13       XCHX,1  E     -        056
 0102   14       INCR,2  C     -        062                                        C     CONSTANT -- ANY TYPE OF SINGLE-
 0104   15       INCR,1  C     -        066                                              PRECISION CONST.  STORED AS IS.
 0106   16       TIX,2   A     -        072
 0107   17       TIX,1   A     -        076

 0108   20       XAD,2   E     -        102
 0109   21       XAD,1   E     -        106
 0110   22       XSU,2   E     -        112
 0111   23       XSU,1   E     -        116
 0112   24       BZE     A     -        122
 0113   25       GOTO    A     U    YES 126     GO TO
 0114   26       BPL     A     -        132
 0115   27       BMN     A     -        136

 0116   30       CALL    A     U    YES 142
 0117   31       STQ     E     -        146     ITA
 0118   32       RTB     F     U        152
 0119   33       BHIZ    A     -        156
 0120   34 (SWITCH CODES)
 0121   35
 0122   36       BOVB    F     -        172
 0123   37       BOV     A     -        176

 012301 40       CALRB   A     B    YES 142

R01231  MODES IN                        OPERAND MODES (FOR BEWARING END BANK)    MODES OUT

R01232  -   DON'T CARE                  D   DOUBLE (2 WORDS)                     -   NO CHANGE
R01233  D   DOUBLE                      M   MATRIX (18 WORDS)                    B   UNKNOWN, REQUIRE BASIC INSTR. NEXT.
R01234  DT  DOUBLE OR TRIPLE            S   SINGLE (1 WORD)                      D   DOUBLE
R01235  V   VECTOR                      T   TRIPLE (3 WORDS)                     I   UNKNOWN, REQUIRE INTERPRETIVE NEXT.
R01236                                  V   VECTOR (6 WORDS)                     T   TRIPLE
R01237  NOTE THAT FOR VXSC AND V/SC,                                             U   UNKNOWN
R01238  IF MODE IN = DT, OP MODE = V, AND IF MODE IN = U OR V, OP MODE = D.      V   VECTOR

# Page 16
#      @AGC BLOCK II INTERPRETIVE CODES: ASSEMBLY RULES FOR BLK2                 USER'S OWN PAGE NO.   3        PAGE  13

P0124   SWITCH CODES, SUFFIX 10 CODE 34.

R0125                   ADDR  MODE  RH  OCT   ADDRESS   ALTERNATE
R0126                   TYPE  OUT   OP  CODE  ADDITIVE  SPELLING                                ADDRESS CODES

 0128   00       BONSET SW+A   -        162    00000                               A     ANY 15-BIT ADDRESS -- 0-52,
 0130   01       SETGO  SW+A   U    YES 162    00020                                     100-3777, 20000-167777.  STORED
 0132   02       BOFSET SW+A   -        162    00040                                     AS IS.
 0134   03       SET    SW     -        162    00060

 0136   04       BONINV SW+A   -        162    00100                               SW    SWITCH BIT NUMBER -- 0-357.
 0138   05       INVGO  SW+A   U    YES 162    00120                                     STORED WITH SWITCH WORD NUMBER
 0140   06       BOFINV SW+A   -        162    00140                                     0-17 (THE INTEGER QUOTIENT OF
 0142   07       INVERT SW     -        162    00160     INV                             N/15) IN BITS 12-9 AND THE BIT-
 0144                                                                                    WITHIN-WORD NUMBER (00-16
 0146   10       BONCLR SW+A   -        162    00200                                     OCTAL, THE REMAINDER OF N/15)
 0148   11       CLRGO  SW+A   U    YES 162    00220                                     IN BITS 4-1.  THIS IS THE ONLY
 0150   12       BOFCLR SW+A   -        162    00240                                     INSTANCE OF NUMBERING BITS FROM
 0152   13       CLEAR  SW     -        162    00160     CLR                             LEFT TO RIGHT.  357 = 239D.

 0154   14       BON    SW+A   -        162    00300
 0155   16       BOFF   SW+A   -        162    00340     BOF



R0156   SUFFIX 000 CODES, UNARY OPERATIONS.

R0157                   MODE  MODE  RH  OCT   ALTERNATE
R0158                    IN   OUT   OP  CODE  SPELLING

 0159   00       EXIT    -     B    YES 000
 0160   01       SQRT    DT    -        010
 0161   02       SIN     DT    -        020    SINE
 0162   03       COS     DT    -        030    COSINE
 0163   04       ASIN    DT    -        040    ARCSIN
 0164   05       ACOS    DT    -        050    ARCCOS
 0165   06       DSQ     DT    -        060
 0166   07       ROUND   DT    D        070

 0167   10       DCOMP   DT    -        100
 0168   11       VDEF    DT    V        110
 0169   12       UNIT    V     -        120
 0170   13       ABS     DT    -        130
 0171   14       VSQ     V     D        140
 0172   15       STADR   -     -    YES 150
 0173   16       RVQ     -     U    YES 160    ITCQ                                IF QPRET POINTS TO ERASABLE, USE
 0174   17       PUSH    -     -        170                                        GOTO  QPRET , NOT RVQ.

 0175   20       VCOMP   V     -        100
 0176   23       ABVAL   V     D        130

# Page 17
#      @AGC BLOCK II INTERPRETIVE CODES: ASSEMBLY RULES FOR BLK2                 USER'S OWN PAGE NO.   4        PAGE  14

P0177   SUFFIX 100 CODES, SHORT SHIFT OPERATIONS.

R0178                   MODE  OCT CODE

 0179   00       SL1R    D      004
 0180   01       SR1R    D      014
 0181   02       SL1     DT     024
 0182   03       SR1     DT     034
 0183   04       SL2R    D      044
 0184   05       SR2R    D      054
 0185   06       SL2     DT     064
 0186   07       SR2     DT     074

 0187   10       SL3R    D      104
 0188   11       SR3R    D      114
 0189   12       SL3     DT     124
 0190   13       SR3     DT     134
 0101   14       SL4R    D      144
 0192   15       SR4R    D      154
 0193   16       SL4     DT     164
 0194   17       SR4     DT     174

 0195   20       VSL1    V      004
 0196   21       VSR1    V      014
 0197   22       VSL2    V      024
 0198   23       VSR2    V      034
 0199   24       VSL3    V      044
 0200   25       VSR3    V      054
 0201   26       VSL4    V      064
 0202   27       VSR4    V      074

 0203   30       VSL5    V      104
 0204   31       VSR5    V      114
 0205   32       VSL6    V      124
 0206   33       VSR6    V      134
 0207   34       VSL7    V      144
 0208   35       VSR7    V      154
 0209   36       VSL8    V      164
 0210   37       VSR8    V      174



R0211   STORE CODES, ADDRESS CONSTANTS.  COMPLEMENTED IF POSITIONED AS THE OPERAND OF A STADR CODE.

R0213                   ADDR   PUSH  MODE  OCTAL  INDEX,1   INDEX,2   LOAD*
R0214                   TYPE    UP   OUT   CODE   ADDITIVE  ADDITIVE  ADDITIVE                  ADDRESS CODES

 0216   00-02    STORE  E       -     -    00000   02000     04000       -         A14   SEE SUFFIX 01 CODES.
 0218   03-10    STODL  E+A14   YES   D    06000   02000     04000     06000       A     SEE SUFFIX 10 CODES.
 0220   11-16    STOVL  E+A14   YES   V    22000   02000     04000     06000       E     SEE SUFFIX 10 CODES.
 0222   17       STCALL E+A     NO    U    36000     -         -         -

back to top