Revision 649f2bd1dbc5702edbc4cbacf44d25ba3ccd8cc9 authored by Felix Ruess on 09 July 2013, 09:34:43 UTC, committed by Felix Ruess on 09 July 2013, 19:17:16 UTC
- krooz: don't use TIM2 for PWM
- change to 6 ticks per usec to fit all frequencies
- on the F1 we assume to run at 72MHz for HCLK and both timer clocks
  TIM1 -> APB2 = HCLK = 72MHz
  TIM2 -> 2 * APB1 = 2 * 36MHz = 72MHz
- on the F4 we assume 2 * AHB clock:
  TIM1 -> 2 * APB2 = 168MHz
  TIM2 -> 2 * APB1 = 84MHz
1 parent 60a6d89
Raw File
baro_mpl3115.xml
<!DOCTYPE module SYSTEM "module.dtd">

<module name="baro_mpl3115" dir="sensors">
  <doc>
    <description>Baro MPL3115A2 (I2C)</description>
    <define name="MPL3115_I2C_DEV" value="i2cX" description="select which i2c peripheral to use (default i2c0)"/>
  </doc>

  <header>
    <file name="baro_mpl3115.h"/>
  </header>
  <init fun="baro_mpl3115_init()"/>
  <periodic fun="baro_mpl3115_read_periodic()" freq="5."/>
  <event fun="baro_mpl3115_read_event()"/>

  <makefile>
    <file name="baro_mpl3115.c"/>
    <file name="mpl3115.c" dir="peripherals"/>
  </makefile>

</module>
back to top