Revision 649f2bd1dbc5702edbc4cbacf44d25ba3ccd8cc9 authored by Felix Ruess on 09 July 2013, 09:34:43 UTC, committed by Felix Ruess on 09 July 2013, 19:17:16 UTC
- krooz: don't use TIM2 for PWM
- change to 6 ticks per usec to fit all frequencies
- on the F1 we assume to run at 72MHz for HCLK and both timer clocks
  TIM1 -> APB2 = HCLK = 72MHz
  TIM2 -> 2 * APB1 = 2 * 36MHz = 72MHz
- on the F4 we assume 2 * AHB clock:
  TIM1 -> 2 * APB2 = 168MHz
  TIM2 -> 2 * APB1 = 84MHz
1 parent 60a6d89
Raw File
humid_sht_i2c.xml
<!DOCTYPE module SYSTEM "module.dtd">

<module name="humid_sht_i2c" dir="meteo">
  <doc>
    <description>Sensirion SHT25 humidity sensor (I2C)</description>
    <define name="SCP_I2C_DEV" value="i2cX" description="select i2c peripheral to use (default i2c0)"/>
  </doc>
  <header>
    <file name="humid_sht_i2c.h"/>
  </header>
  <init fun="humid_sht_init_i2c()"/>
  <periodic fun="humid_sht_periodic_i2c()" freq="4" delay="0"/>
  <periodic fun="humid_sht_p_temp()" freq="4" delay="6"/>
  <periodic fun="humid_sht_p_humid()"  freq="4" delay="9"/>
  <event fun="humid_sht_event_i2c()"/>
  <makefile target="ap">
    <file name="humid_sht_i2c.c"/>
  </makefile>
</module>

back to top