swh:1:snp:32555a3fd8878f019c2ebd6c964bc1edcaeff337
Revision 67dbf54a3b03881c7b683801fa49ca1f2c4c3bcf authored by Jacek Anaszewski on 02 July 2013, 10:13:00 UTC, committed by Jonathan Cameron on 16 July 2013, 07:51:57 UTC
This patch fixes improper in_pressure_scale output that is
returned by the lps331ap barometer sensor driver. According
to the documentation the pressure after applying the scale has to
be expressed in kilopascal units. With erroneous implementation
the scale value larger by two orders of magnitude is returned -
2441410 instead of 24414.

Signed-off-by: Jacek Anaszewski <j.anaszewski@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Acked-by: Denis Ciocca <denis.ciocca@st.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
1 parent 8f6817a
History
Tip revision: ffb4d94b4314655cea60ab7962756e6bab72fc7e authored by Linus Torvalds on 30 September 2022, 23:25:52 UTC
Merge tag 'drm-fixes-2022-10-01' of git://anongit.freedesktop.org/drm/drm