Revision 7ff57e98fb78ad94edafbdc7435f2d745e9e6bb5 authored by Fabio M. De Francesco on 23 February 2022, 10:02:52 UTC, committed by Jakub Kicinski on 24 February 2022, 17:09:33 UTC
smc_pnetid_by_table_ib() uses read_lock() and then it calls smc_pnet_apply_ib()
which, in turn, calls mutex_lock(&smc_ib_devices.mutex).

read_lock() disables preemption. Therefore, the code acquires a mutex while in
atomic context and it leads to a SAC bug.

Fix this bug by replacing the rwlock with a mutex.

Reported-and-tested-by: syzbot+4f322a6d84e991c38775@syzkaller.appspotmail.com
Fixes: 64e28b52c7a6 ("net/smc: add pnet table namespace support")
Confirmed-by: Tony Lu <tonylu@linux.alibaba.com>
Signed-off-by: Fabio M. De Francesco <fmdefrancesco@gmail.com>
Acked-by: Karsten Graul <kgraul@linux.ibm.com>
Link: https://lore.kernel.org/r/20220223100252.22562-1-fmdefrancesco@gmail.com
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
1 parent e13ad14
Raw File
sht4x.rst
.. SPDX-License-Identifier: GPL-2.0

Kernel driver sht4x
===================

Supported Chips:

  * Sensirion SHT4X

    Prefix: 'sht4x'

    Addresses scanned: None

    Datasheet:

      English: https://www.sensirion.com/fileadmin/user_upload/customers/sensirion/Dokumente/2_Humidity_Sensors/Datasheets/Sensirion_Humidity_Sensors_SHT4x_Datasheet.pdf

Author: Navin Sankar Velliangiri <navin@linumiz.com>


Description
-----------

This driver implements support for the Sensirion SHT4x chip, a humidity
and temperature sensor. Temperature is measured in degree celsius, relative
humidity is expressed as a percentage. In sysfs interface, all values are
scaled by 1000, i.e. the value for 31.5 degrees celsius is 31500.

Usage Notes
-----------

The device communicates with the I2C protocol. Sensors can have the I2C
address 0x44. See Documentation/i2c/instantiating-devices.rst for methods
to instantiate the device.

Sysfs entries
-------------

=============== ============================================
temp1_input     Measured temperature in millidegrees Celcius
humidity1_input Measured humidity in %H
update_interval The minimum interval for polling the sensor,
                in milliseconds. Writable. Must be at least
                2000.
=============== ============================================