Revision f4a8e31ed84ec646c158824f423cb22d1f362bbf authored by Uwe Kleine-König on 01 July 2021, 08:27:55 UTC, committed by Thierry Reding on 08 July 2021, 14:09:30 UTC
As the last call to ep93xx_pwm_apply() might have exited early if
state->enabled was false, the values for period and duty_cycle stored in
pwm->state might not have been written to hardware and it must be
ensured that they are configured before enabling the PWM.

Fixes: 6d45374af539 ("pwm: ep93xx: Implement .apply callback")
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
1 parent 7d6d4aa