https://github.com/virtualagc/virtualagc
Revision 3577d0b1de1ac147c1710524517c563b2bfe231c authored by Ronald Burkey on 30 May 2021, 19:14:00 UTC, committed by GitHub on 30 May 2021, 19:14:00 UTC
Issue 1143: Fix various symbol name and other minor typos
2 parent s bc21d6b + 8d274f6
Raw File
Tip revision: 3577d0b1de1ac147c1710524517c563b2bfe231c authored by Ronald Burkey on 30 May 2021, 19:14:00 UTC
Merge pull request #1147 from smithery1/Issue/1143
Tip revision: 3577d0b
INTER-BANK_COMMUNICATION.agc
### FILE="Main.annotation"
## Copyright:	Public domain.
## Filename:	INTER-BANK_COMMUNICATION.agc
## Purpose:	Part of the source code for Colossus build 237.  
##		This is for the Command Module's (CM) Apollo Guidance
##		Computer (AGC), for Apollo 8.
## Assembler:	yaYUL
## Contact:	Onno Hommes <ohommes@alumni.cmu.edu>
## Website:	www.ibiblio.org/apollo/index.html
## Page Scans:	www.ibiblio.org/apollo/ScansForConversion/Colossus237/
## Mod history:	2010-05-22 OH	Adapted from corresponding Colossus 249 file.
##		2010-12-04 JL	Remove Colossus 249 header comments. Change to double-has page numbers.
##		2011-02-07 JL	Minor fixes.
##		2017-01-01 RSB	Proofed comment text using octopus/ProoferComments,
##				but no found.

## Page 1070
# 	   THE FOLLOWING ROUTINE CAN BE USED TO CALL A SUBROUTINE IN ANOTHER BANK. IN THE BANKCALL VERSION, THE
# CADR OF THE SUBROUTINE IMMEDIATELY FOLLOWS THE  TC BANKCALL  INSTRUCTION, WITH C(A) AND C(L) PRESERVED.

		BLOCK	02
		COUNT	02/BANK

BANKCALL	DXCH	BUF2		# SAVE INCOMING A,L.
		INDEX	Q		# PICK UP CADR.
		CA	0
		INCR	Q		# SO WE RETURN TO THE LOC. AFTER THE CADR.

# 	   SWCALL IS IDENTICAL TO BANKCALL, EXCEPT THAT THE CADR ARRIVES IN A.

SWCALL		TS	L
		LXCH	FBANK		# SWITCH BANKS, SAVING RETURN.
		MASK	LOW10		# GET SUB-ADDRESS OF CADR.
		XCH	Q		# A,L NOW CONTAINS DP RETURN.
		DXCH	BUF2		# RESTORING INPUTS IF THIS IS A BANKCALL.
		INDEX	Q
		TC	10000		# SETTING Q TO SWRETURN.

SWRETURN	XCH	BUF2 +1		# COMES HERE TO RETURN TO CALLER. C(A,L)
		XCH	FBANK		# ARE PRESERVED FOR RETURN.
		XCH	BUF2 +1
		TC	BUF2


# 	   THE FOLLOWING ROUTINE CAN BE USED AS A UNILATERAL JUMP WITH C(A,L) PRESERVED AND THE CADR IMMEDIATELY
# FOLLOWING THE TC POSTJUMP INSTRUCTION.

POSTJUMP	XCH	Q		# SAVE INCOMING C(A).
		INDEX	A		# GET CADR.
		CA	0

# 	   BANKJUMP IS THE SAME AS POSTJUMP, EXCEPT THAT THE CADR ARRIVES IN A.

BANKJUMP	TS	FBANK
		MASK	LOW10
		XCH	Q		# RESTORING INPUT C(A) IF THIS WAS A
Q+10000		INDEX	Q		# POSTJUMP.
PRIO12		TCF	10000		# PRIO12 = TCF   10000 = 12000

## Page 1071
# 	   THE FOLLOWING ROUTINE GETS THE RETURN CADR SAVED BY SWCALL OR BANKCALL AND LEAVES IT IN A.

MAKECADR	CAF	LOW10
		MASK	BUF2
		AD	BUF2 +1
		TC	Q


SUPDACAL	TS	MPTEMP
		XCH	FBANK		# SET FBANK FOR DATA.
		EXTEND
		ROR	SUPERBNK	# SAVE FBANK IN BITS 15-11, AND
		XCH	MPTEMP		#  SUPERBANK IN BITS 7-5.
		MASK	LOW10
		XCH	L		# SAVE REL. ADR. IN BANK, FETCH SUPERBITS.
		INHINT			# BECAUSE RUPT DOES NOT SAVE SUPERBANK.
		EXTEND
		WRITE	SUPERBNK	# SET SUPERBANK FOR DATA.
		INDEX	L
		CA	10000		# PINBALL (FIX MEM DISP) PREVENTS DCA HERE
		XCH	MPTEMP		# SAVE 1ST WD, FETCH OLD FBANK AND SBANK.
		EXTEND
		WRITE	SUPERBNK	# RESTORE SUPERBANK.
		RELINT
		TS	FBANK		# RESTORE FBANK.
		CA	MPTEMP		# RECOVER FIRST WORD OF DATA.
		RETURN			# 24 WDS. DATACALL 516 MU, SUPDACAL 432 MU

## Page 1072
# 	   THE FOLLOWING ROUTINES ARE IDENTICAL TO BANKCALL AND SWCALL EXCEPT THAT THEY ARE USED IN INTERRUPT.

IBNKCALL	DXCH	RUPTREG3	# USES RUPTREG3,4 FOR DP RETURN ADDRESS.
		INDEX	Q
		CAF	0
		INCR	Q

ISWCALL		TS	L
		LXCH	FBANK
		MASK	LOW10
		XCH	Q
		DXCH	RUPTREG3
		INDEX	Q
		TC	10000

ISWRETRN	XCH	RUPTREG4
		XCH	FBANK
		XCH	RUPTREG4
		TC	RUPTREG3

# 2. USPRCADR ACCESSES INTERPRETIVE CODING IN OTHER THAN THE USER'S FBANK. THE CALLING SEQUENCE IS AS FOLLOWS:

#					  L        TC     USPRCADR
#					  L+1      CADR   INTPRETX        INTPRETX IS THE INTERPRETIVE CODING
#					                                  RETURN IS TO L+2

USPRCADR	TS	LOC		# SAVE A
		CA	BIT8
		TS	EDOP		# EXIT INSTRUCTION TO EDOP
		CA	BBANK
		TS	BANKSET		# USER'S BBANK TO BANKSET
		INDEX	Q
		CA	0
		TS	FBANK		# INTERPRETIVE BANK TO FBANK
		MASK	LOW10		# YIELDS INTERPRETIVE RELATIVE ADDRESS
		XCH	Q		# INTERPRETIVE ADDRESS TO Q, FETCHING L+1
		XCH	LOC		# L+1 TO LOC, RETRIEVING ORIGINAL A
		TCF	Q+10000

## Page 1073
# THERE ARE FOUR POSSIBLE SETTINGS FOR CHANNEL 07. (CHANNEL 07 CONTAINS THE SUPERBANK SETTING.)
#                                           PSEUDO-FIXED     OCTAL PSEUDO
# SUPERBANK     SETTING     S-REG. VALUE    BANK NUMBERS     ADDRESSES
# ----------    -------     ------------     ------------     ------------

# SUPERBANK 3     0XX       2000 - 3777        30 - 37       70000 - 107777   (WHERE XX CAN BE ANYTHING AND
#                                                                             WILL USUALLY BE SEEN AS 11)
# SUPERBANK 4     100       2000 - 3777        40 - 47       110000 - 127777  (AS FAR AS IT CAN BE SEEN,
#                                                                             ONLY BANKS 40-43 WILL EVER BE
#                                                                             AND ARE PRESENTLY AVAILABLE)
# SUPERBANK 5     101       2000 - 3777        50 - 57       130000 - 147777  (PRESENTLY NOT AVAILABLE TO
#                                                                             THE USER)
# SUPERBANK 6     110       2000 - 3777        60 - 67       150000 - 167777  (PRESENTLY NOT AVAILABLE TO
#                                                                             THE USER)
# ***  THIS ROUTINE MAYBE CALLED BY ANY PROGRAM LOCATED IN BANKS 00 - 27.  I.E., NO PROGRAM LIVING IN ANY
# SUPERBANK SHOULD USE SUPERSW.  ***

# SUPERSW MAYBE CALLED IN THIS FASHION:

#          CAF    ABBCON          WHERE  --  ABBCON   BBCON  SOMETHIN --
#          TCR    SUPERSW         (THE SUPERBNK BITS ARE IN THE BBCON)
#          ...      ...
#           .        .
#           .        .

# OR IN THIS FASHION :

#          CAF    SUPERSET        WHERE SUPERSET IS ONE OF THE FOUR AVAILABLE
#          TCR    SUPERSW         SUPERBANK BIT CONSTANTS:
#          ...      ...                                   SUPER011 OCTAL  60
#           .        .                                    SUPER100 OCTAL 100
#           .        .                                    SUPER101 OCTAL 120
#                                                         SUPER110 OCTAL 140

SUPERSW		EXTEND
		WRITE	SUPERBNK	# WRITE BITS 7-6-5 OF THE ACCUMULATOR INTO
					# CHANNEL 07
		TC	Q		# TC TO INSTRUCTION FOLLOWING
					#   TC  SUPERSW
back to top