Revision 847d7970defb45540735b3fb4e88471c27cacd85 authored by Daniel J Blueman on 13 March 2014, 11:43:01 UTC, committed by Ingo Molnar on 14 March 2014, 10:05:36 UTC
For systems with multiple servers and routed fabric, all
northbridges get assigned to the first server. Fix this by also
using the node reported from the PCI bus. For single-fabric
systems, the northbriges are on PCI bus 0 by definition, which
are on NUMA node 0 by definition, so this is invarient on most
systems.

Tested on fam10h and fam15h single and multi-fabric systems and
candidate for stable.

Signed-off-by: Daniel J Blueman <daniel@numascale.com>
Acked-by: Steffen Persvold <sp@numascale.com>
Acked-by: Borislav Petkov <bp@suse.de>
Cc: <stable@vger.kernel.org>
Link: http://lkml.kernel.org/r/1394710981-3596-1-git-send-email-daniel@numascale.com
Signed-off-by: Ingo Molnar <mingo@kernel.org>